Aromatic Polyurethane Coating
MSDS
MATERIAL SAFETY DATA SHEET
I. CHEMICAL PRODUCT AND COMPANY INFORMATION
- PRODUCT IDENTIFICATION
EnergyGuard Aromatic Polyurethane Coating
- Packaging: buckets, drums, totes
- Chemical Name: Polyurethane Elastomeric Roof Coating
- CAS Number: Blend
- COMPANY IDENTIFICATION
- Lexis Coatings
1025 Rose Creek Dr
Ste 620 #138
Woodstock, GA 30189
770-755-1820
- FOR EMERGENCIES
- 1-877-454-0052
II. HAZARDS IDENTIFICATION
- CAUTION
- Prolonged or repeated contact may cause skin or eye irritation. May be harmful if swallowed. Protect from freezing.
- HMIS Rating
- Health: 2
Flammability: 1
Reactivity: 0
Personal Protection Index: S
- EYE:
- Contact may cause eye irritation.
- SKIN:
- Can cause moderate skin irritation.
- INHALATION
- Avoid breathing vapors or mists. Prolonged or excessive inhalation may cause respiratory tract irritation. May cause allergic respiratory reaction.
- INGESTION
- Harmful if swallowed. Can burn mouth, throat and stomach.
- CHRONIC EFFECTS
- Sensitized (allergic) individuals may show allergenic lung and/or skin reaction. After an individual is diagnosed as sensitive to isocyanates, no exposure should be permitted. Chronic effects of overexposure to xylene may include kidney or liver damage.
- REPRODUCTIVE HAZARDS
- Exposure to Xylene may damage developing fetus.
- CARCINOGENICITY INFORMATION
- No known cancer hazards.
- MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
- Asthma-like conditions may cause additional breathing problem.
III. COMPOSITION AND INFORMATION ON INGREDIENTS
- COMPONENT LISTING:
-
| Chemical Name |
Amount |
CAS Number |
| Xylene |
25% |
1330-20-7 |
- (See Section 8 for exposure guidelines.)
- (See Section 15 for regulatory information.)
- HAZARDS DISCLOSURE
- This product contains hazardous materials that are subject to reporting under Section 313 of Title III: Xylene.
- As defined under Sara 311 and 312, this product contains materials that are fire hazards.
V. FIRE FIGHTING MEASURES
- FLAMMABLE PROPERTIES
- COC Flash Point: 80.0 F
- Auto Ignition Temperature: N/A
- FLAMMABLE LIMITS IN AIR
- LEL: 1 %
- EXTINGUISHING MEDIA
- Carbon dioxide, foam or dry powder.
- FIRE & EXPLOSION HAZARDS
- Vapors may flow along surfaces to distant ignition sources and flash back. Closed containers exposed to heat may explode. Contact with strong oxidizers may cause fire.
- FIRE FIGHTING INSTRUCTIONS
- As in any fire, wear self-contained breathing apparatus pressure-demand MSHA/NIOSH (approved or equivalent) and full protective gear.
VI. ACCIDENTAL RELEASE MEASURES
- SAFEGUARDS (PERSONNEL):
- Wear safety goggles. Wear appropriate protective equipment.
- INITIAL CONTAINMENT:
- Contain spilled material. Absorb spills with inert or absorbent material.
- LARGE SPILLS PROCEDURE:
- Ventilate enclosed areas or wear self-contained breathing appratus. Recover free liquid in closed containers. Keep out of sewers and water courses. Clean area with absorbent material.
VII. HANDLING AND STORAGE
- RECOMMENDED STORAGE TEMPERATURE:
- Minimum: 15.6 C (60.1 F)
Maximum: 26.7 C (80.1 F)
- SHELF LIFE (in original, sealed containers):
- 6 months @ 26.7 C
- HANDLING (PERSONNEL):
- Avoid prolonged or repeated contact with skin. Wash hands thoroughly after handling.
- HANDLING (PHYSICAL ASPECTS):
- Agitate containers before use. Keep from freezing. Keep out of reach of children.
- STORAGE PRECAUTIONS:
- Avoid extreme temperatures. Keep container closed when not in use. Store in a cool dry place.
VIII. EXPOSURE CONTROLS / PERSONAL PROTECTION
- EYE / FACE PROTECTION REQUIREMENTS:
- Wear safety glasses. A respiratory protection program that meets OSHA's 29 CFR 1910-134 and ANSI Z88-2 requirements must be followed whenever workplace conditions warrant a respirator's use.
- SKIN PROTECTION REQUIREMENTS:
- Selection of specific items such as gloves, boots, apron or full-body suit will depend on operation. Wash hands thoroughly after handling.
- RESPIRATORY PROTECTION REQUIREMENTS:
- Use NIOSH approved vapor canister or supplied-air respiratory protection in confined spaces that are not ventilated. Use adequate ventilation to keep concentration of vapors below exposure limits.
- EXPOSURE GUIDELINES:
- No Information Available.
IX. PHYSICAL AND CHEMICAL PROPERTIES
| FORM |
Liquid |
| COLOR |
White |
| ODOR |
Strong Solvent Odor |
| BOILING POINT |
281 - 284 F |
| EVAPORATION RATE |
Slower than Ether |
| % VOLATILE VOLUME |
31.6% |
| VAPOR DENSITY |
Heavier than Air |
| DENSITY |
9.1 lbs. |
X. STABILITY AND REACTIVITY
- STABILITY:
- Stable. May decompose when heated.
- POLYMERIZATION:
- Polymerization may occur in contact with moisture or other materials which react with isocyanates or when product is heated.
- DECOMPOSITION:
- Decomposition will not occur if handled and stored properly.
XI. TOXICOLOGICAL INFORMATION
No information available.
XII. ECOLOGICAL INFORMATION
No information available.
XIII. DISPOSAL CONSIDERATIONS
- WASTE DISPOSAL:
- Treat or dispose of waste material in accordance with all local, state/provincial, and national requirements.
XIV. TRANSPORTATION INFORMATION
- PRODUCT LABEL: EnergyGuard Aromatic Polyurethane Roof Coating
- D.O.T. SHIPPING NAME: Flammable
- D.O.T. HAZARD CLASS: Liquids, n.o.s. (Xylene), 3
- UN NUMBER: UN 1993, PG III
XV. REGULATORY INFORMATION
- SARA TITLE III - Section 313
- XYLENE (1330-20-7)
- CERCLA Hazardous Substances
- XYLENE (1330-20-7) -- RQ 1000 lb
- RCRA Hazardous Substances
- XYLENE (1330-20-7) -- RCRA Code: U239
- Title V
- XYLENE (1330-20-7)
- SC Toxic Air Pollutants List
- XYLENE (1330-20-7)
XVI. OTHER INFORMATION
The information contained in this MSDS is accurate to the best of our knowledge. It is intended to assist the user in his evaluation of the product's hazards, and safety precautions to be taken in its use. We do not assume liability for the use of, or reliance on this information, nor do we guarantee its accuracy or completeness.